Assessment of operator reliability in ultrasound of the median and ulnar nerve using Bland-Altman analysis

  • Currently, there is no standardized method to evaluate operator reliability in nerve ultrasound. A short prospective protocol using Bland-Altman analysis was developed to assess the level of agreement between operators with different expertise levels. A control rater without experience in nerve ultrasound, three novices after two months of training, an experienced rater with two years of experience, and a reference rater performed blinded ultrasound examinations of the left median and ulnar nerve in 42 nerve sites in healthy volunteers. The precision of Bland-Altman agreement analysis was tested using the Preiss–Fisher procedure. Intraclass correlation coefficients (ICC), coefficients of variation, and Bland-Altman limits of agreement were calculated. The sample size calculation and Preiss–Fisher procedure showed a sufficient precision of Bland–Altman agreement analysis. Limits of agreement of all trained novices ranged from 2.0 to 2.9 mm\(^{2}\) and were within the test’s maximum tolerated difference. Ninety-five percent confidence intervals of limits of agreement revealed a higher precision in the experienced rater’s measurements. Operator reliability in nerve ultrasound of the median and ulnar nerve arm nerves can be evaluated with a short prospective controlled protocol using Bland–Altman statistics, allowing a clear distinction between an untrained rater, trained novices after two months of training, and an experienced rater.

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar
Metadaten
Author:Jörg PhilippsORCiDGND, Hannah MorkGND, Maria KatzGND, Mark KnaupGND, Kira BeyerGND, Kristina SpiesGND, Johannes CorbachGND, Peter Dieter SchellingerGND
URN:urn:nbn:de:hbz:294-90138
DOI:https://doi.org/10.3390/diagnostics11112134
Parent Title (English):Diagnostics
Publisher:MDPI
Place of publication:Basel
Document Type:Article
Language:English
Date of Publication (online):2022/06/01
Date of first Publication:2021/11/17
Publishing Institution:Ruhr-Universität Bochum, Universitätsbibliothek
Tag:Open Access Fonds
Bland-Altman agreement analysis; cross-sectional area; nerve ultrasound; reliability; training effect
Volume:11
Issue:11, Artikel 2134
First Page:2134-1
Last Page:2134-8
Note:
Article Processing Charge funded by the Open Access Publication Fund of Ruhr-Universität Bochum.
Institutes/Facilities:Johannes Wesling Klinikum Minden, Klinik für Neurologie und Neurogeriatrie
Dewey Decimal Classification:Technik, Medizin, angewandte Wissenschaften / Medizin, Gesundheit
open_access (DINI-Set):open_access
Licence (English):License LogoCreative Commons - CC BY 4.0 - Attribution 4.0 International